Absolute Maximum Ratings  
Operating Temperature  
Table 9.  Absolute Maximum Ratings
Symbol
Description
Min
Typ
Max
Units
Notes
T
STG
Storage Temperature 
-55
+25
+125
o
C
Higher storage temperatures 
reduce data retention time. 
Recommended storage temper-
ature is +25°C ± 25°C. Storage 
temperatures above 65
o
degrades reliability. Maximum 
combined storage and operational 
time at +125°C is 7000 hours.
T
A
Ambient Temperature with Power Applied
-40
+125
o
C
Vdd
Supply Voltage on Vdd Relative to Vss
-0.5
+5.75
V
V
IO
DC Input Voltage
Vss - 0.5
Vdd + 0.5
V
V
IOZ
DC Voltage Applied to Tri-state
Vss - 0.5
Vdd + 0.5
V
I
MIO
Maximum Current into any Port Pin
-25
+25
mA
ESD
Electro Static Discharge Voltage
2000
V
Human Body Model ESD.
LU
Latch-up Current
200
mA
Table 10.  Operating Temperature
Symbol
Description
Min
Typ
Max
Units
Notes
T
A
Ambient Temperature
-40
+125
o
C
T
J
Junction Temperature
-40
+135
o
C
The temperature rise from ambient 
to junction is package specific. See 
on page 29. The user must limit the 
power consumption to comply with 
this requirement.