Maximum Ratings 
Exceeding maximum ratings may shorten the useful life of the
device. User guidelines are not tested.
Storage Temperature  ................................. –65°C to +150°C
Ambient Temperature with Power Applied.. –55°C to +125°C
Supply Voltage on V
DD
 Relative to GND ........–0.5V to +2.9V
Supply Voltage on V
DDQ
 Relative to GND ..... –0.5V to + V
DD
DC Applied to Outputs in High-Z  ........ –0.5V to V
DDQ 
+ 0.3V
DC Input Voltage
............................... –0.5V to V
DD
 + 0.3V
Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage (MIL-STD-883, M. 3015)...  >2001V
Latch Up Current ....................................................  >200 mA
Operating Range
Range
Ambient
Temperature (T
A
)
V
DD
V
DDQ
Com’l
0°C to +70°C 
1.8 ± 0.1V
1.4V to V
DD
Ind’l
–40°C to +85°C
Electrical Characteristics
Over the Operating Range
 
DC Electrical Characteristics 
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
DD
Power Supply Voltage
1.7
1.8
1.9
V
V
DDQ
IO Supply Voltage
1.4
1.5
V
DD
V
V
OH
Output HIGH Voltage
V
DDQ
/2 – 0.12
V
DDQ
/2 + 0.12
V
V
OL
Output LOW Voltage
V
DDQ
/2 – 0.12
V
DDQ
/2 + 0.12
V
V
OH(LOW)
Output HIGH Voltage
I
OH 
=
 −0.1 mA, Nominal Impedance
V
DDQ
 – 0.2
V
DDQ
V
V
OL(LOW)
Output LOW Voltage
I
OL
 = 0.1 mA, Nominal Impedance
V
SS
0.2
V
V
IH
Input HIGH Voltage
V
REF 
+ 0.1
V
DDQ 
+ 0.15
V
V
IL
Input LOW Voltage
–0.15
V
REF
 – 0.1
V
I
X
Input Leakage Current 
GND 
≤ V
I
 
≤ V
DDQ
−2
2
μA
I
OZ
Output Leakage Current
GND 
≤ V
I
 
≤ V
DDQ, 
Output Disabled
−2
2
μA
V
REF
Input Reference Voltage
Typical Value = 0.75V
0.68
0.75
0.95
V
I
DD 
V
DD
 Operating Supply 
V
DD 
= Max., I
OUT 
= 0mA,
f = f
MAX
 = 1/t
CYC
300 MHz
1040
mA
333 MHz
1120
mA
375 MHz
1240
mA
I
SB1
Automatic Power down 
Current
Max. V
DD
, Both Ports 
Deselected, V
IN
 
≥ V
IH
 or 
V
IN
 
≤ V
IL
, f = f
MAX
 = 1/t
CYC
,
 
Inputs Static
300 MHz
280
mA
333 MHz
300
mA
375 MHz
310
mA
AC Electrical Characteristics 
Over the Operating Range 
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
IH
Input HIGH Voltage
V
REF
 + 0.2
V
DDQ
 + 0.24
V
V
IL 
Input LOW Voltage
–0.24
V
REF
 – 0.2
V
Notes
17. Power up: Assumes a linear ramp from 0V to V
DD
(min) within 200 ms. During this time V
IH 
< V
DD 
and V
DDQ 
< V
DD.
18. Outputs are impedance controlled. I
OH
 = 
(V
DDQ
/2)/(RQ/5) for values of 175
Ω <= RQ <= 350Ωs.
19. Outputs are impedance controlled. I
OL
 = (V
DDQ
/2)/(RQ/5) for values of 175
Ω <= RQ <= 350Ωs.
20. V
REF
 (min) = 0.68V or 0.46V
DDQ
, whichever is larger; V
REF
 (max) =
 
0.95V or 0.54V
DDQ
, whichever is smaller.
21. The operation current is calculated with 50% read cycle and 50% write cycle.