Electrical Characteristics 
Over the Operating Range (continued)
1399B-15
1399B-20
Parameter
Description
Test Conditions
Min.
Max.
Min.
Max.
Unit
V
OH
Output HIGH Voltage
V
CC
 = Min., I
OH
 = –2.0 mA
2.4
2.4
V
V
OL
Output LOW Voltage
V
CC
 = Min., I
OL
 = 4.0 mA
0.4
0.4
V
V
IH
Input HIGH Voltage
2.2
V
CC
+0.3V
2.2
V
CC
+0.3V
V
V
IL
Input LOW Voltage
–0.3
0.8
–0.3
0.8
V
I
IX
Input Load Current
–1
+1
–1
+1
µ
A
I
OZ
Output Leakage Current
GND 
 V
I
 
 V
CC
,
Output Disabled
–5
+5
–5
+5
µ
A
I
OS
Output Short Circuit 
Current
[2]
V
CC
 = Max., V
OUT
 = GND
–300
–300
mA
I
CC
V
CC
 Operating 
Supply Current
V
CC
 = Max., I
OUT
 = 0 mA, 
f = f
MAX
 = 1/t
RC
50
45
mA
I
SB1
Automatic CE Power-Down 
Current — TTL Inputs
Max. V
CC
, CE 
 V
IH
V
IN
 
 V
IH
, or V
IN 
 V
IL
f = f
MAX
5
5
mA
L
4
4
mA
I
SB2
Automatic CE Power-Down 
Current — CMOS Inputs
[3]
Max. V
CC
, CE 
 V
CC
–0.3V, V
IN
 
 
V
CC
 – 0.3V, or V
IN
 
 0.3V, 
WE
V
CC
–0.3V or WE
 0.3V, 
f=f
MAX
500
500
µ
A
L
50
50
µ
A
Capacitance
Parameter
Description
Test Conditions
Max.
Unit
C
IN
: Addresses
Input Capacitance
T
A
 = 25
°
C, f = 1 MHz, V
CC
 = 3.3V
5
pF
C
IN
: Controls
6
pF
C
OUT
Output Capacitance
6
pF
AC Test Loads and Waveforms
Note:
4.
Tested initially and after any design or process changes that may affect these parameters.
3.0V
3.3V
OUTPUT
R1 317
Ω
R2
351
Ω
C
L
INCLUDING
JIG AND
SCOPE
GND
90%
10%
90%
10%
3 ns
3 ns
OUTPUT
1.73V
Equivalent to:
THÉVENIN EQUIVALENT
ALL INPUT PULSES
167
Ω