Cypress CY7C1318BV18 Manual De Usuario

Descargar
Página de 31
CY7C1316BV18, CY7C1916BV18
CY7C1318BV18, CY7C1320BV18
Document Number: 38-05621 Rev. *D
Page 21 of 31
I
DD 
V
DD
 Operating Supply
V
DD 
= Max,
I
OUT 
= 0 mA,
f = f
MAX
 = 1/t
CYC
200 MHz
(x8)
575
mA
(x9)
580
(x18)
600
(x36)
635
167 MHz
(x8)
490
mA
(x9)
490
(x18)
510
(x36)
540
I
SB1
Automatic Power Down 
Current
Max V
DD
Both Ports Deselected, 
V
IN
 
≥ V
IH
 or V
IN
 
≤ V
IL
 
f = f
MAX
 = 1/t
CYC
,
 
Inputs Static
300 MHz
(x8)
315
mA
(x9)
315
(x18)
325
(x36)
350
278 MHz
(x8)
305
mA
(x9)
305
(x18)
315
(x36)
330
250 MHz
(x8)
300
mA
(x9)
300
(x18)
300
(x36)
320
200 MHz
(x8)
285
mA
(x9)
285
(x18)
290
(x36)
300
167 MHz
(x8)
280
mA
(x9)
280
(x18)
285
(x36)
295
AC Electrical Characteristics 
Over the Operating Range 
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
IH
Input HIGH Voltage
V
REF
 + 0.2
V
V
IL 
Input LOW Voltage
V
REF
 – 0.2
V
Electrical Characteristics 
 (continued)
DC Electrical Characteristics 
Over the Operating Range 
[12]
Parameter
Description
Test Conditions
Min
Typ
Max
Unit