Cypress CY7C1318BV18 Manual De Usuario

Descargar
Página de 31
CY7C1316BV18, CY7C1916BV18
CY7C1318BV18, CY7C1320BV18
Document Number: 38-05621 Rev. *D
Page 24 of 31
Output Times
t
CO
t
CHQV
C/C Clock Rise (or K/K in single 
clock mode) to Data Valid
0.45
0.45
0.45
0.45
0.50
ns
t
DOH
t
CHQX
Data Output Hold after Output C/C 
Clock Rise (Active to Active)
–0.45
–0.45
–0.45
–0.45
–0.50
ns
t
CCQO
t
CHCQV
C/C Clock Rise to Echo Clock Valid
0.45
0.45
0.45
0.45
0.50
ns
t
CQOH
t
CHCQX
Echo Clock Hold after C/C Clock 
Rise 
–0.45
–0.45
–0.45
–0.45
–0.50
ns
t
CQD
t
CQHQV 
Echo Clock High to Data Valid
0.27
0.27
0.30
0.35
0.40
ns
t
CQDOH
t
CQHQX
Echo Clock High to Data Invalid
–0.27
–0.27
–0.30
–0.35
–0.40
ns
t
CHZ
t
CHQZ
Clock (C/C) Rise to High-Z 
(Active to High-Z) 
0.45
0.45
0.45
0.45
0.50
ns
t
CLZ
t
CHQX1
Clock (C/C) Rise to Low-Z 
–0.45
–0.45
–0.45
–0.45
–0.50
ns
DLL Timing
t
KC Var
t
KC Var
Clock Phase Jitter
0.20
0.20
0.20
0.20
0.20
ns
t
KC lock
t
KC lock
DLL Lock Time (K, C)
1024
1024
1024
1024
1024
Cycles
t
KC Reset
t
KC Reset
K  Static  to  DLL  Reset
30
30
30
30
30
ns
Switching Characteristics
 (continued)
Over the Operating Range 
[20, 21] 
Cypress 
Parameter
Consortium 
Parameter
Description
300 MHz
278 MHz
250 MHz
200 MHz
167 MHz
Unit
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Notes
24. t
CHZ
, t
CLZ
 are specified with a load capacitance of 5 pF as in (b) of 
 on page 22. Transition is measured 
±100 mV from steady-state voltage.
25. At any voltage and temperature t
CHZ
 is less than t
CLZ 
and t
CHZ
 less than t
CO
.