Cypress STK16C88-3 Manual De Usuario

Descargar
Página de 14
STK16C88-3
Document Number: 001-50594 Rev. **
Page 6 of 14
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the
device. These user guidelines are not tested.
Storage Temperature  ................................. –65
°C to +150°C
Temperature under bias .............................. –55
°C to +125°C
Supply Voltage on V
CC
 Relative to GND.......... –0.5V to 4.5V
Voltage on Input Relative to Vss ............–0.6V to V
CC
 + 0.5V
Voltage on DQ
0-7
  ...................................–0.5V to Vcc + 0.5V
Power Dissipation ......................................................... 1.0W
DC output Current (1 output at a time, 1s duration) .... 15 mA
Operating Range
Range
Ambient Temperature
V
CC
Commercial
0
°C to +70°C
3.0V to 3.6V
Industrial
-40
°C to +85°C
3.0V to 3.6V
DC Electrical Characteristics
Over the operating range (V
CC
 = 3.0V to 3.6V) 
Parameter
Description
Test Conditions
Min
Max
Unit
I
CC1
Average V
CC
 Current
t
RC
 = 35 ns
Dependent on output loading and cycle rate. 
Values obtained without output loads.
I
OUT
 = 0 mA.
Commercial
50
mA
Industrial
52
mA
I
CC2
Average V
CC
 Current 
during STORE
All Inputs Do Not Care, V
CC
 = Max
Average current for duration t
STORE
3
mA
I
CC3
Average V
CC
 Current at 
t
RC
= 200 ns, 5V, 25°C 
Typical
WE > (V
CC
 – 0.2V). All other inputs cycling.
Dependent on output loading and cycle rate. Values obtained 
without output loads.
8
mA
I
SB1
Average V
CC
 Current 
(Standby, Cycling TTL 
Input Levels)
t
RC
=35ns, CE > V
IH
Commercial
18
mA
Industrial
19
mA
I
SB2
[3]
V
CC
 Standby Current
(Standby, Stable CMOS 
Input Levels)
CE > (V
CC
 – 0.2V). All others V
IN 
< 0.2V or > (V
CC
 – 0.2V). 
1
mA
I
IX
Input Leakage Current
V
CC
 = Max, V
SS
 < V
IN 
< V
CC
-1
+1
μA
I
OZ
Off State Output 
Leakage Current
V
CC
 = Max, V
SS
 < V
IN 
< V
CC
, CE or OE > V
IH 
or WE < V
IL
-1
+1
μA
V
IH
Input HIGH Voltage
2.2
V
CC
 + 
0.5
V
V
IL
Input LOW Voltage
V
SS
 – 
0.5
0.8
V
V
OH
Output HIGH Voltage
I
OUT
 = –4 mA 
2.4
V
V
OL
Output LOW Voltage
I
OUT
 = 8 mA 
0.4
V
Data Retention and Endurance
Parameter
Description
Min
Unit
DATA
R
Data Retention
100
Years
NV
C
Nonvolatile STORE Operations
1,000
K
Note
3. CE > V
IH
 will not produce standby current levels until any nonvolatile cycle in progress has timed out.