25 
 
 
 
25
 
Serial 2
Serial 1
J6
J5
 
 
Figure 12. 
J5 and J6 Connectors layout 
 
Both can be set as RS232 but only one (J5) can be set as RS422-485.  
Refer to the following tables for the serial ports pinout assignment in RS232/422/485 modes. 
 
 
 
Table 9. 
J5, J6 Serial Port Connectors in RS232 mode 
Pin  Signal
Function 
DB25
DB9
DCD 
Data Carrier Detect
DSR 
Data Set Ready 
RX 
Receive Data 
RTS 
Request To Send 
TX 
Transmit data 
CTS 
Clear To Send 
DTR 
Data Terminal 
Ready 
20 
RI 
Ring Indicator 
22 
9,10 
GND 
Signal Ground 
 
Table 10. 
J5 Serial Port Connector in RS422-RS485 modes 
RS422 
RS485 
Pin 
Signal 
Function 
In/out
Signal 
Function 
In/out 
Pin 
-TX 
Transmit data 
out 
-TX/-RX
Transmit/Receive data 
out/in 
-- 
Not connected 
-- 
-- 
Not connected 
-- 
+TX 
Transmit Data 
out 
+TX/+RX
Transmit/Receive data 
out/in 
-- 
Not connected 
-- 
-- 
Not connected 
-- 
-RX 
Receive Data 
in 
-- 
Not connected 
-- 
-- 
Not connected 
-- 
-- 
Not connected 
-- 
+RX 
Receive Data 
in 
-- 
Not connected 
-- 
-- 
Not connected 
-- 
-- 
Not connected 
-- 
9,10 
gnd 
Signal ground 
-- 
gnd 
Signal ground 
-- 
9,10 
 
 
  Note. If the Serial port is used in RS485 mode, the bi-directional line must be controlled 
via software, using the Data Terminal Ready (DTR) signal of the serial controller.  
   This signal is defined by bit 0 of the UART Modem Control Register (MCR) and the bi-
directional line is controlled as follows: