Cypress CY8C23433 Manual De Usuario

Descargar
Página de 37
CY8C23433, CY8C23533
Document Number: 001-44369 Rev. *B
Page 15 of 37
Absolute Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the device. User guidelines are not tested. 
Operating Temperature
 
 
Table 9.  Absolute Maximum Ratings
Symbol
Description
Min
Typ
Max
Units
Notes
T
STG
Storage Temperature 
-55
25
+100
°C
Higher storage temperatures 
reduce data retention time. 
Recommended storage 
temperature is +25°C ± 25°C. 
Extended duration storage 
temperatures above 65°C 
degrade reliability.
T
A
Ambient Temperature with Power Applied
-40
+85
°C
Vdd
Supply Voltage on Vdd Relative to Vss
-0.5
+6.0
V
V
IO
DC Input Voltage
Vss - 0.5
Vdd + 0.5
V
V
IOZ
DC Voltage Applied to Tri-state
Vss - 0.5
Vdd + 0.5
V
I
MIO
Maximum Current into any Port Pin
-25
+50
mA
ESD
Electro Static Discharge Voltage
2000
V
Human Body Model ESD.
LU
Latch-up Current
200
mA
Table 10.  Operating Temperature
Symbol
Description
Min
Typ
Max
Units
Notes
T
A
Ambient Temperature
-40
+85
°C
T
J
Junction Temperature
-40
+100
°C
The temperature rise from 
ambient to junction is package 
specific. See 
The user must limit the power 
consumption to comply with this 
requirement.