Power Up Sequence in DDR-II SRAM
DDR-II SRAMs must be powered up and initialized in a
predefined manner to prevent undefined operations. During
power up, when the DOFF is tied HIGH, the DLL is locked after
1024 cycles of stable clock.
Power Up Sequence
Apply power and drive DOFF LOW (all other inputs can be 
HIGH or LOW)
Apply V
DD
 before V
DDQ
Apply V
DDQ 
before V
REF
 or at the same time as V
REF
After the power and clock (K, K) are stable take DOFF HIGH
The additional 1024
 
cycles of clocks are required for the DLL 
to lock.
DLL Constraints
DLL uses K clock as its synchronizing input. The input must 
have low phase jitter, which is specified as t
KC Var
.
The DLL functions at frequencies down to 120 MHz.
If the input clock is unstable and the DLL is enabled, then the 
DLL may lock onto an incorrect frequency, causing unstable 
SRAM behavior. To avoid this, provide 1024 cycles stable clock 
to relock to the desired clock frequency.
Power Up Waveforms
> 1024 Stable clock
Start  Normal 
Operation
DOFF
Stabl(< +/-  0.1V  DC  per 50ns )
Fix  High (or tied to VDDQ)
K
K
DDQ
DD
V
V
/
DDQ
DD
V
V
/
Clock Start (Clock Starts after                       Stable)
DDQ
DD
V
V
/
~ ~
~~
Unstable Clock