Cypress CY7C1511KV18 Manual De Usuario

Descargar
Página de 31
CY7C1511KV18, CY7C1526KV18
CY7C1513KV18, CY7C1515KV18
Document Number: 001-00435 Rev. *E
Page 25 of 31
Output Times
t
CO
t
CHQV
C/C Clock Rise (or K/K in single 
clock mode) to Data Valid
0.45
0.45
0.45
0.45
0.50
ns
t
DOH
t
CHQX
Data Output Hold after Output C/C 
Clock Rise (Active to Active)
–0.45
–0.45
–0.45
–0.45
–0.50
ns
t
CCQO
t
CHCQV
C/C Clock Rise to Echo Clock Valid
0.45
0.45
0.45
0.45
0.50
ns
t
CQOH
t
CHCQX
Echo Clock Hold after C/C Clock 
Rise
–0.45
–0.45
–0.45
–0.45
–0.50
ns
t
CQD
t
CQHQV 
Echo Clock High to Data Valid
0.25
0.27
0.30
0.35
0.40
ns
t
CQDOH
t
CQHQX
Echo Clock High to Data Invalid
–0.25
–0.27
–0.30
–0.35
–0.40
ns
t
CQH
t
CQHCQL
Output Clock (CQ/CQ) HIGH 
1.25
1.4
1.75
2.25
2.75
ns
t
CQHCQH
t
CQHCQH
CQ Clock Rise to CQ Clock Rise 
(rising edge to rising edge) 
1.25
1.4
1.75
2.25
2.75
ns
t
CHZ
t
CHQZ
Clock (C/C) Rise to High-Z 
(Active to High-Z) 
0.45
0.45
0.45
0.45
0.50
ns
t
CLZ
t
CHQX1
Clock (C/C) Rise to Low-Z 
–0.45
–0.45
–0.45
–0.45
–0.50
ns
PLL Timing
t
KC Var
t
KC Var
Clock Phase Jitter
0.20
0.20
0.20
0.20
0.20
ns
t
KC lock
t
KC lock
PLL  Lock  Time  (K,  C)
20
20
20
20
20
μs
t
KC Reset
t
KC Reset
K Static to PLL Reset
30
30
30
30
30
ns
Switching Characteristics 
 (continued)
Over the Operating Range 
[22, 23] 
Cypress
Parameter
Consortium 
Parameter
Description
333 MHz
300 MHz
250 MHz
200 MHz
167 MHz
Unit
Min Max Min Max Min Max Min Max Min Max
Notes
25. These parameters are extrapolated from the input timing parameters (t
CYC
/2 - 250 ps, where 250 ps is the internal jitter). These parameters are only guaranteed by 
design and are not tested in production
26. t
CHZ
, t
CLZ
, are specified with a load capacitance of 5 pF as in (b) of 
. Transition is measured ± 100 mV from steady-state voltage.
27. At any voltage and temperature t
CHZ
 is less than t
CLZ
 and t
CHZ
 less than t
CO