Cypress CY7C1411JV18 Manual De Usuario

Descargar
Página de 28
CY7C1411JV18, CY7C1426JV18
CY7C1413JV18, CY7C1415JV18
Document Number: 001-12557 Rev. *C
Page 15 of 28
TAP Controller Block Diagram
TAP Electrical Characteristics 
Over the Operating Range 
Parameter
Description
Test Conditions
Min
Max
Unit
V
OH1
Output HIGH Voltage
I
OH 
=
 −2.0 mA
1.4
V
V
OH2
Output HIGH Voltage
I
OH 
=
 −100 μA
1.6
V
V
OL1
Output LOW Voltage
I
OL
 = 2.0 mA
0.4
V
V
OL2
Output LOW Voltage
I
OL
 = 100 
μA
0.2
V
V
IH
Input HIGH Voltage
0.65V
DD
V
DD 
+ 0.3
V
V
IL
Input LOW Voltage
–0.3
0.35V
DD
V
I
X
Input and Output Load Current 
GND 
≤ V
I
 
≤ V
DD
–5
5
μA
0
0
1
2
.
.
29
30
31
Boundary Scan Register
Identification Register
0
1
2
.
.
.
.
108
0
1
2
Instruction Register
Bypass Register
Selection
Circuitry
Selection
Circuitry
TAP Controller
TDI
TDO
TCK
TMS
Notes
12. These characteristics pertain to the TAP inputs (TMS, TCK, TDI and TDO). Parallel load levels are specified in the 
 Table.
13. Overshoot: V
IH
(AC) < V
DDQ
 + 0.85V (Pulse width less than t
CYC
/2), Undershoot: V
IL
(AC) > 
1.5V (Pulse width less than t
CYC