87C196CB SUPPLEMENT
6-2
AD_COMMAND 
Address:
Reset State:
1FACH
C0H
The A/D command (AD_COMMAND) register selects the A/D channel number to be converted, 
controls whether the A/D converter starts immediately or with an EPA command, and selects the 
conversion mode.
7
0
M1
M0
GO
ACH2
ACH1
ACH0
Bit 
Number
Bit 
Mnemonic
Function
7:6
Reserved; for compatibility with future devices, write zeros to these bits.
5:4
M1:0
A/D Mode
These bits determine the A/D mode.
M1
M0
Mode
0
0
10-bit conversion
0
1
8-bit conversion
1
0
threshold detect high
1
1
threshold detect low
3
GO
A/D Conversion Trigger
Writing this bit arms the A/D converter. The value that you write to it 
determines at what point a conversion is to start.
0 = EPA initiates conversion
1 = start immediately
2:0
ACH2:0
A/D Channel Selection
Write the A/D conversion channel number to these bits. The 87C196CB 
has eight A/D channel inputs, numbered 0–7.
While a threshold-detection mode is selected for an analog input pin, no other conversion can be 
started. If another value is loaded into AD_COMMAND, the threshold-detection mode is disabled 
and the new command is executed.
††
It is the act of writing to the GO bit, rather than its value, that starts a conversion. Even if the GO bit 
has the desired value, you must set it again to start a conversion immediately or clear it again to 
arm it for an EPA-initiated conversion.
Figure 6-1.  A/D Command (AD_COMMAND) Register