7-29
CAN SERIAL COMMUNICATIONS CONTROLLER
7.6
ENABLING THE CAN INTERRUPTS
The CAN controller has a single interrupt input (INT13) to the interrupt controller. (Generally,
PTS interrupt service is not useful for the CAN controller because the PTS cannot readily deter-
mine the source of the CAN controller’s multiplexed interrupts.) To enable the CAN controller’s
interrupts, you must enable the interrupt source by setting the CAN bit in INT_MASK1 (see Ta-
ble 7-2 on page 7-3) and
 globally enable interrupt servicing (by executing the EI instruction). In
addition, you must set bits in the CAN control register (Figure 7-17) and the individual message
objects’ control register 0 (Figure 7-18) to enable the individual interrupt sources within the CAN
controller. 
CAN_CON  
(87C196CB)
Address:
Reset State:
1E00H
01H
Program the CAN control (CAN_CON) register to control write access to the bit timing registers, to 
enable and disable CAN interrupts, and to control access to the CAN bus.
7
0
87C196CB
CCE
EIE
SIE
IE
INIT
Bit
Number
Bit
Mnemonic
Function
7
Reserved; for compatibility with future devices, write zero to this bit.
6
CCE
Change Configuration Enable
5:4
Reserved; for compatibility with future devices, write zeros to these bits.
3
EIE
Error Interrupt Enable
This bit enables and disables the bus-off and warn interrupts.
0 = disable bus-off and warn interrupts 
1 = enable bus-off and warn interrupts 
2
SIE
Status-change Interrupt Enable
This bit enables and disables the successful reception (RXOK), successful 
transmission (TXOK), and error code change (LEC2:0) interrupts.
0 = disable status-change interrupt 
1 = enable status-change interrupt 
When the SIE bit is set, the CAN controller generates a successful 
reception (RXOK) interrupt request each time it receives a valid message, 
even if no message object accepts it.
Figure 7-17.  CAN Control (CAN_CON) Register