Recovering from Problems
6-5
Recovering from 
Problems
Use the following procedure to recover from operating problems or 
module failure. Each of these steps is explained in more detail in the 
sections that follow.
Verify that the DMM can communicate with the ATM Backbone 
SwitchModule
Verify that the correct software versions are installed.
Verify that the critical configuration parameters settings of the ATM 
Backbone SwitchModule match those of the ATM switch to which it is 
connected.
Verify ATM OC-3 Card Functions.
Verify ATM Signalling Functions.
Verify LEC Functions.
Verify Bridging Configuration.
Verify that a CoreBuilder 5000 SwitchModule has a vbridge configured 
on the same bridge port as the CoreBuilder 5000 ATM Backbone 
SwitchModule bridge port.
Verify Data Movement.
10 Verify ATM OC-3 Switchover Functions.
Record your results for the following procedures. The information may 
be required if you need to contact your technical support 
representative.
Verifying DMM
Communication
To isolate a problem in the ATM Backbone SwitchModule, you must be 
able to communicate with the ATM Backbone SwitchModule from the 
DMM.
Use the following command to verify that the DMM can communicate 
with the ATM Backbone SwitchModule:
CB5000> show module all
Check that the display lists the ATM Backbone SwitchModule model 
number (6602M-MOD).