Table 6-17 PIO data transfer to/from device 
 
PIO timing parameters 
 
Mode 0
ns 
Mode 1
ns 
Mode 2 
ns 
Mode 3 
ns 
Mode 4
ns 
Note
t
0
 
Cycle 
time 
(min)
600 383 240 180 120 1,4 
t
1
 
Address valid to DIOR-/DIOW- setup
(min)
70 
50 
30 
30 
25 
 
t
2
 
DIOR-/DIOW-             16-bit 
 
(min)
 
165 
 
125 
 
100 
 
80 
 
70 
 
 
t
2i
 
DIOR-/DIOW- recovery time 
(min)
70 
25 
t
3
 
DIOW- 
data 
setup 
(min)
60 45 30 30 20  
t
4
 
DIOW- 
data 
hold 
(min)
30 20 15 10 10  
t
5
 
DIOR- 
data 
setup 
(min)
50 35 20 20 20  
t
6
 
DIOR- 
data 
hold 
(min)
5 5 5 5 5  
t
6Z
 
DIOR- 
data 
tri-state 
(max)
30 30 30 30 30 2 
t
9
 
DIOR-/DIOW- to address valid hold 
(min)
20 
15 
10 
10 
10 
 
t
RD
 
Read Data Valid to IORDY active 
(if IORDY initially low after t
A
(min)
0 0 0 0 0  
t
A
 
IORDY 
Setup 
time 
  35 35 35 35 35 3 
t
B
 
IORDY 
Pulse 
Width 
(max)
1250 1250 1250 1250 1250   
t
C
 
IORDY assertion to release  
(max)
 
NOTES 
 
1 t
0
 is the minimum total cycle time, t
2
 is the minimum command active time, and t
2i
 is the minimum command recovery 
time or command inactive time.  The actual cycle time equals the sum of the actual command active time and the actual 
command inactive time.  The three timing requirements of t
0
, t
2
, and t
2i
 shall be met.  The minimum total cycle time 
requirements are greater than the sum of t
2
 and t
2i
.  This means a host implementation may lengthen either or both t
2
 or 
t
2i
 to ensure that t
0
 is equal to or greater than the value reported in the devices IDENTIFY DEVICE data.  A device 
implementation shall support any legal host implementation. 
2 This parameter specifies the time from the negation edge of DIOR- to the time that the data bus is no longer driven by 
the device (tri-state). 
3The delay from the activation of DIOR- or DIOW- until the state of IORDY is first sampled.  If IORDY is inactive 
then the host shall wait until IORDY is active before the PIO cycle is completed.  If the device is not driving IORDY 
negated at the t
A
 after the activation of DIOR- or DIOW-, then t
5
 shall be met and t
RD
 is not applicable.  If the device is 
driving IORDY negated at the time t
A
 after the activation of DIOR- or DIOW-, then t
RD
 shall be met and t
5
 is not 
applicable. 
4 Mode may be selected at the highest mode for the device if CS(1:0) and AD(2:0) do not change between read or write 
cycles or selected at the highest mode supported by the slowest device if CS(1:0) or AD(2:0) do change between read or 