Renesas 32176 Manual De Usuario

Descargar
Página de 92
32176 Group 
Starter Kit User’s Manual M3A-2152 
REJ10B0224-0300/Rev.3.00 
Jan. 2007 
Page 13 of 82 
 
5.1.2  M3A-2152 Evaluation Board Power Supply and Settings 
The following shows how to set the M3A-2152 Evaluation Board.   
Use a 5V DC power supply to feed power to the M3A-2152 Evaluation Board.     
Use included 5V power supply cable to connect the 5V DC power supply and CN2 connector 
included with the M3A-2152 Evaluation Board. The Connecting when Feeding Power to the 
M3A-2152 Evaluation Board is shown in Figure 5.2. 
 
 
 
 
 
 
 
 
 
 
 
Figure 5.2    Connecting when Feeding Power to the M3A-2152 Evaluation Board 
 
Table 5.3    Jumper Settings before Shipmen 
Jumper Name 
Jumper Settings 
Remarks 
H1 
Shorted between 1-2 
Uses power from CN2 connector to AVCC power supply 
Note: For detail about the power supply settings, refer to Appendix 3 M3A-2152G02 Product Standards 
 
5.1.3  Connecting M3A-2152 Evaluation Board and M32100T-EZ-E 
Use included 10-pin flat cable to connect M32100T-EZ-E and XCN1 connector included with the 
M3A-2152 Evaluation Board.   
The method for Connecting M3A-2152 Evaluation Board and M32100T-EZ-E is shown in Figure 
5.3. 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 5.3    Connecting M3A-2152 Evaluation Board and M32100T-EZ-E 
 
5.1.4  System Power-on Sequence when M3A-2152G52A in Use 
When turning on power, turn on M32100T-EZ-E first and then the M3A-2152 Evaluation 
Board. 
When turning off power, turn off the M3A-2152 Evaluation Board first and then 
M32100T-EZ-E. 
 When turning on power again after turning off power, wait for 10 seconds. 
Power to M32100T-EZ-E can be fed from USB cable. 
 
 
 
Note: Unless the Starter Kit is powered on this sequence, the kit may operate erratically or break down. 
 
4.75 - 5.25V DC  power supply
M3A-2152 evaluation board
CN2
H1
M3A-2152 evaluation board
XCN1
10-pin flat cable
M32100T-EZ-E
SDI I/F