6.2.2 Starting 
M3S-KD32R 
Before  starting  M3S-KD32R,  make  sure  the  hardware  components  have  been  set  up  in 
accordance with the instructions in 5.2 Hardware Setup when M3A-2152G52 in Use, and that 
the Starter Kit hardware system (M3A-2152 Evaluation Board and M3A-2195 SDI Interface 
Board) have been powered on. Make sure that M3S-KD32R cannot be started unless the power to 
the hardware system is turned on. 
 
To start M3S-KD32R, 
choose [Start] -> [Programs] -> [RENESAS-TOOL] -> [KD32R V4.00 Release 1] -> [KD32R] from 
Start menu of Windows. When M3S-KD32R starts, the initialize dialog box shown in Figure 6.2 
appears. So initialize   
M3S-KD32R from this dialog box. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 6.8    M3S-KD32R Initialize Dialog Box 
 
Setting MCU File 
To set 32176 Group, specify MCU file “32176.mcu”. 
This MCU file is stored in directory: ( installed location) \ KD32R \ MCUFILES.   
Click the MCU tab in the initialize dialog box (see Figure 6.2) and then the “Refer” button. This 
brings up a dialog box for setting MCU files. In this dialog box, select the MCU file. 
 
Setting Model 
While the MCU tab is open, select the appropriate MCU type from Model selection. 
 
Setting Mode 
While the MCU tab is open, select the appropriate MCU operation mode from Mode selection. 
 
Setting CPU Clock   
While the MCU tab is open, select the “40” for the appropriate CPU Clock. 
 
Setting PC Communication Mode 
While the MCU tab is open, select “AUTO” for Type, and “378h” or “278h” for I/O Address. 
 