32176 Group 
Starter Kit User’s Manual M3A-2152 
REJ10B0224-0300/Rev.3.00 
Jan. 2007 
Page 48 of 82 
 
2.3  MOD Select Circuit   
This circuit is used to set operation modes of the M32R/ECU. The MOD0 power supply is 
configured in such a way that MOD0 is switched from the EXTMOD0 signal of extension connector 
(CON2) by using a jumper (J8). 
The MOD1 power supply defaults to 0 V. The MOD2 power supply is fixed to 0 V. 
 
 
J2
U1
M32R/ECU
MOD1
3
1
2
VCC
J4
TX6
3
1
2
VCC
EXTMOD0
MOD0
MOD2
 
 
Note: TX6 is not mounted but it only has one pattern available. 
 
Figure 2.3    MOD Select Circuit 
 
Table 2.3    Operation Mode Settings 
MOD0 MOD1 MOD2
Function 
0 0 0 
• When flash reprogramming is disabled: Single-chip mode 
• When flash reprogramming is enabled: Flash rewrite + single-chip mode 
1 0 0 
• When flash reprogramming is disabled: Processor mode 
• When flash reprogramming is enabled: Boot model + flash E/W enable 
0 1 0 
External 
extension 
mode 
1 1 0 
Settings 
inhibited 
 
Table 2.4    MOD Select Circuit (Jumper) 
Name Default  Condition 
Description 
{
 
Shorted 
between 1–2 
MOD0 is controled by EXTMOD0 or is set to 0 unless it is 
controled by EXTMOD0 
J4 
 
Shorted 
between 2–3 
Sets MOD0 to 1 
{
 
Shorted 
between 1–2 
Sets MOD1 to 0 
J2 
 
Shorted 
between 2–3 
Sets MOD1 to 1 
Note: The J2 jumper is shorted by soldering.