Renesas 32176 Manual De Usuario

Descargar
Página de 92
32176 Group 
Starter Kit User’s Manual M3A-2152 
REJ10B0224-0300/Rev.3.00 
Jan. 2007 
Page 54 of 82 
 
2.8  Analog Port Input Control Circuit   
The analog port input control circuit is used to control the status of the M32R/ECU ports AD0IN0 
and AD0IN1 by using VR controls VOL0 and VOL1. 
 
 
U1
M32R/ECU
AVCC
AD0IN0
H3 1    2
H4 1    2
AVCC
VOL0
VOL1
AD0IN1
 
 
Figure 2.9    Analog Port Input Control Circuit 
 
Table 2.12    Analog Port Input Control (Jumper) 
Name Default  Condition 
Description 
{
 
Shorted 
between 1–2 
Uses VR control (VOL0) 
H3 
 
Open 
between 1–2 
Does not use VR control (VOL0) 
{
 
Shorted 
between 1–2 
Uses VR control (VOL1) 
H4 
 
Open 
between 1–2 
Does not use VR control (VOL1) 
Note: The H3 and H4 jumpers are shorted by soldering.