Page 9 
Digital Display Wall Clock Guide 
 
AC Return) Attach the ground wire of the cord (normally green) to the green ground screw located on the 
inside back of the case. Slide the lens and circuit board assembly back into the case, replace the end cap 
and secure with the four phillips head screws. 
DDC4-RS 
Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel 
assembly out of the case. Carefully flip the front panel assembly over and lay it face down on a clean, 
smooth work surface. Remove one of the vent caps from the case of the wall clock and route the power 
cord through it to the back of the display panel. (If the power cord will be routed through the back-of-the-
clock conduit access, route the cord through the gang box and conduit access hole to the back of the circuit 
board assembly). Strip away 1/2" of the protective shield from each wire of the power cord. Locate the two 
black wires leading from J1 (see figure 2, page 9) and attach the AC In line of the cord to one and the AC 
Return line to the other  (normally black is AC In and white is AC Return). Attach the ground wire of the 
cord, (normally green) to the green ground screw located on the inside back of the case. Slide the front 
panel display back into the case, replace the end cap and secure with the two phillips head screws. 
 
Wiring Installation - DDC2/4-RS Series 
Secondary Wiring 
The DDC Wall Clock comes with a detachable wiring harness to make installation easier. The wiring 
harness can be removed from the back of the main circuit board at position J1 as shown in figure 2 so 
wiring from the master clock can be attached to the wiring harness with the clock's Electronic Assembly 
removed. The leads from the wiring harness should be connected as shown in the diagrams in Appendix A. 
RS485 Wiring 
The DDC Wall Clock comes with a detachable wiring block to make installation easier. The wiring block 
can be removed from the back of the main circuit board at position JP4 as shown in figure 2 so wiring from 
the master clock can be attached without the need of holding the Wall Clock itself. Wiring should be 
connected as shown in the diagrams in Appendix C. 
DDC-TC Wiring 
The DDC Wall Clock comes with a detachable wiring block to make installation easier. The wiring block 
can be removed from the back of the main circuit board at position JP2 as shown in figure 2 so wiring from 
the Timer Control Panel can be attached without the need of holding the Wall Clock itself. Wiring should 
be connected as shown in the diagrams in Appendix D.