DDC2 / 4-RS Wiring 
Digital Display Wall Clock Guide 
Page 34 
National Synchronous Wired  
115VAC 
From 
Master Clock 
       To 
Other Clocks
H
M
BLU / WHT
Run
Correction
BRN / WHT
BLK
BLK
AC Return
Clock will correct minutes hourly at HH:00 and 
hour and minutes twice daily at 6:00. 
For 24VAC applications, use 
wiring shown on page 18 
7
8
  Set switches 1-5 of S1 as shown. 
 
 Indicates depressed side of switch 
OPEN
1 2
3 4
5
6