Lathem DDC4 Manual De Usuario

Descargar
Página de 63
DDC-TC Timer Control Panel 
Digital Display Wall Clock Guide 
Page 50 
Appendix D - DDC-TC Timer Control Panel 
Wiring 
The DDC-TC can be connected to the DDC Series Wall Clock with a 6 conductor CAT3 or CAT5 network 
cable. The DDC-TC can be mounted up to 200 feet from the DDC Series Wall Clock. The DDC-TC comes 
with 6 wire nuts to connect the network cable to the 6 control wires mounted on the back of the DDC-TC. 
The 6 control wires include Up, Down, Hours, Minutes, Beeper and Ground. To wire the DDC-TC to the 
DDC Series Wall Clock locate JP2 and JP4 on the back of the DDC display panel (see figure 2, page 10), 
pass the wire through a knockout at both the DDC-TC double-gang box (not included), the DDC Wall 
Clock and follow the diagram below. 
 
                                     
Beeper
Ground
Minutes
Hours
Up
Down
Rear View - Used for Reference
 
 
                      
DDC Series Wall Clock
JP2
JP4
Ground
Beeper
Down
Up
Minutes
Hours
DDC-TC Panel
CAT3 or CAT5 Cable - 200 feet maximum
Ground
Beeper
Down
Up
Minutes
Hours
D-
D+
Green
Green / White
Brown
Blue
Blue / White
Brown / White
Wire colors may vary. Keep in pairs as shown