Toshiba MA-1595-1 Series Manual De Usuario

Descargar
Página de 218
5. DISPLAY
 
EO1-11152 
 
5.1 Upper Row (16-digit dot windows)
 
5- 3 
(3) Error Messages (in any mode except “LOCK”) 
When an error occurs, an error message (programmable) is displayed, with an error buzzer generated (a long 
tone). 
 
 
 
 
 
 
Read the Error Message, depress the [C] key to cancel the error status and tone, operate the sequence again 
after removing the cause of the error. 
The following table shows the cause of the error. 
If the error status cannot be cancelled or an error message not listed in the table below is displayed, please 
contact your nearest TOSHIBA TEC representative. 
ERROR MESSAGE TABLE 
Error Message 
(Standard Setting) 
Cause of the Error 
OPERATION ERROR 
Key Sequence or Operation Procedure Error 
MANAGER REQUIRED 
The operation requires a Manager Intervention. 
CLOSE DRAWER 
The drawer must be closed before the operation. 
COMPULSORY CODE 
No code has been entered where it is compulsory. 
COMP DEPOSIT 
Sub-link Department is compulsory, but not yet entered. 
SCALE REQUIRED 
The [SCALE] key has not been depressed where required. 
SCALE OUT 
The scale is malfunctioning. 
PC COMM ERROR 
File Receive Error (when a PC is connected). 
CODE ERROR 
An undefined code has been entered, or the entered code has already been 
defined. 
PROGRAM ERROR 
An additional entry of new PLU or new customer file is not acceptable, 
because the memory of each table is full. 
CALL MANAGER 
The card is not acceptable as a result of Negative Card checking. 
DRAWER LIMIT 
A media pick up operation is now required. 
LINK PLU ERROR 
PLU linkage error such as when a sub-link PLU is not programmed in the Link-
PLU Table. 
COMPULSORY SLIP 
The operation requires a endorsement print. 
CDV ERROR 
Check Digit Value Error 
COMP CHECK NO. 
Performing the negative card check is necessary before finalizing a sale by a 
media key which has the compulsory status of the negative card check. 
X/Z IN PROGRESS 
Read/Reset operation is unavailable during the consolidation of the 
communication buffer by PC (or master terminal). 
ALREADY RESERVED 
Read/Reset/Reserve operation was attempted when reset data remained in 
the communication buffer. (in case of the program option to prohibit rewriting 
reset data in the communication buffer) 
UNDER AGE 
Underage person has attempted to buy cigarette or alcoholic beverage. 
COMP QUANTITY 
Quantity Entry Compulsion Error (when this compulsion status is programmed 
to a PLU item). 
PIN ERROR 
EFT Pin Pad Error 
NO RESPONS 
Time-out condition on the EFT terminal 
RECEIPT REQUIRED 
Entry of new sale transaction is attempted before issuing the store receipt. 
RESPONS NG 
Communication error between the ECR and the EFT terminal. 
MISC ERROR 
Other errors 
PAPER END 
Paper is out. 
 
X X X X X X X X X X X X X X X X
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Error Message (max. 16)