Toshiba MA-1595-1 Series Manual De Usuario

Descargar
Página de 218
9. BACKUP FUNCTION
 
EO1-11152 
 
9. BACKUP FUNCTION
 
9- 1 
9. BACKUP FUNCTION 
(ONLY WHEN THE BACKUP MASTER IS CONNECTED) 
 
(1) Function 
•  By connecting the Backup Master Terminal, the various files stored in the Master Terminal can be backed 
up. 
•  The terminal assigned to ID No. 2 will function as a Backup Master Terminal.  By programming ID No. 2 in 
the terminal connection table and downloading this data to each terminal, the system will function as a 
system in which the Backup Master Terminal is connected. 
•  By changing terminal ID from 2 to 1, the Backup Master Terminal will function as the Master Terminal. 
 
< Files to be Backed Up > 
 
PLU Main Table 
(When the PLU inquiry function is used) 
Program data 
Sales data 
PLU Additional Table 
(When the PLU inquiry function is used) 
Program data 
Sales data 
Link PLU Table 
(When the PLU inquiry function is used) 
Program data 
Cashier Table 
(When the floating cashier system is used) 
Program data 
Sales data 
Customer File (Check Track) Table 
Program data 
Sales data 
Negative Card Table 
Program data 
 
NOTES:  1.  Data capture (DC) transaction files are not backed up. 
 
2.  The tables (center files) managed by the Master Terminal and used by each terminal via inquiries 
and PC transmission information tables are backed up. 
 
•  Sales data is backed up on a real-time basis. 
 
When sales data of the Master Terminal is updated, sales data of the Backup Master Terminal is updated 
at the same time. 
 
•  Backup data check function: 
 
Correspondence between the center files and backup data is checked every certain period of time. 
 
•  Backup data update process: 
 
When an error occurs in backup data, the following processing methods can be selected according to the 
program option setting. 
(1)  Automatic data copy 
 
When the version of the center file stored in the Master Terminal is different from that stored in the 
Backup Master Terminal, registration jobs are automatically prohibited, the backup data is properly 
exchanged.  While updating the backup data, each inquiry from the terminals may result in a 
“MASTER IS BUSY” error. 
(2)  Manual data copy 
 
When the version of the center file stored in the Master Terminal is different from that of data stored in 
the Backup Master Terminal, the Master Terminal gives a short beep at the timing of issuing the long 
receipt to warn that the data is not backed up properly.  The operator should update the backup data 
manually.