PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL  2 (cont.)
REFILL
Range: 0 to 155
This function allows the operator to adjust the sensitiv-
ity of the refill circuit. This is mainly a troubleshooting 
feature. Water in different geographical locations can 
have different conductivities. By adjusting the sensitivity 
of the refill circuit, this will allow the brewer to operate 
under various water conditions.
Procedure to set the sensitivity threshold of the refill 
circuit:
NOTE:  Make sure the water in the tank is touching the 
refill probe. 
1.  Press and hold the right hidden button until the 
display  reads  SET  LANGUAGE.  Press  the  right 
hidden button until the display reads REFILL and 
shows a number on both sides of the word.
2.  To adjust the threshold setting, press (-) to decrease 
or (+) to increase the setting.
NOTE: Always make sure that the number on the right 
is larger than the number on the left when water is in 
contact with the refill probe in the tank.
3.  When finished, press and release 
DONE.  This saves 
the new setting and advances to the next function 
screen  SPRAY  OZ/M.  To  exit  programming  and 
return to the MAIN SCREEN, press and release the 
ON/OFF pad.
P2876
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
XXX   REFILL   155
(-)    DONE    (+)
SPRAY OZ/M:  XX.X
(-)    DONE    (+)