Technical Reference  
66 
56K Voice Faxmodem Internal - User’s Guide 
 
Register 
Default 
Function 
   S10 
14 
Sets the duration, in tenths of a second, that the modem 
waits to hang up after loss of carrier. This guard time 
allows the modem to distinguish between a line 
disturbance from a true disconnect (hang up) by the 
remote modem. 
 
 
 
Note: If you set S10 = 255, the modem will not hang up 
when carrier is lost. Dropping DTR hangs up the modem. 
  S11 
70 
Sets the duration and spacing, in milliseconds, for tone 
dialing. 
  S12 
50 
Sets the duration, in fiftieths of a second, of the guard time 
for the escape code sequence (+++). 
  S13 
Bit-mapped register. Select the bit(s) you want on and set 
S13 to the total of the values in the Value column. For 
example, ATS13 = 17 enables bit 0 (value is 1) and bit 4 
(value is 16). 
 
Bit 
Value 
Result 
 
Reset when DTR drops. 
 
Reset non-MNP transmit buffer from 
1.5K to 128 bytes.* 
 
Set backspace key to delete. 
 
On DTR signal, auto dial the number 
stored in NVRAM at position 0. 
 
 
 
16 
At power on/reset, auto dial the 
number stored in NVRAM at position 
0. 
 
32 
Reserved 
 
64 
Disable quick retrains. 
 
 
7        128 
Disconnect on escape code.