2.048Mbps Wireless Modem
TECHNICAL: 0118 931 2233 
 
Figure 3-12. Time Tracer Max Consecutive Errors Graph 
 
Using the same time resolution as the Time Tracer Errors versus Time, this graph displays the 
maximum number of consecutive errors in each time unit. At the top of the graph appears 
information on the maximum number of consecutive errors identified during the tracing 
period, and how much 
time passed since this event. Each column in the graph represents the relative  
number of consecutive errors in the relevant time period. The graph displays the history of 
the last 69 time units according to the defined resolution (“Set Time Tracer Resolution” - 
option 7 in the Counters and Tracers Menu), or the history since the last time the Time Tracer 
was reset (see also page 76). 
 
This tracer is very important, since long bursts of consecutive errors can pass the ARQ error 
correction algorithm uncorrected. The above tracer shows when these long bursts occurred, 
and their length. The longest (isolated) burst of consecutive errors tolerated by the ARQ 
algorithm depends on the delay setting. The following table displays for each delay setting 
the maximum number of consecutive errors and blocked frequency channels resulting in no 
errors at the LIU due to the ARQ algorithm: 
 
 
Table 3-17. Delay Setting 
 
Set Time Tracer Resolution 
 
When the Time Tracer is displayed, you can view up to 69 traced time intervals. 
 
⇒ To set the time intervals: 
 
1.  In the Counters and Tracers menu type 7. The Set Time Tracer Resolution screen 
shows, displaying the current resolution.