Black Box 3600 Manual De Usuario

Descargar
Página de 270
Installation
2-4
Modem 3600
 
Table 2-1. Pin Signal Description s
Pin
EIA- 
232D
CCITT
V.24
Signal
Description
1
101
Shield
No connection
2
BA
103
Trans-
mitted 
Data
Serial digital data (to be 
modulated) from a data terminal or 
other digital data source: 
Synchronous data must be 
accompanied by the modem 
transmit clock (pin 15) or by an 
external data rate clock (pin 24). 
Data transitions should occur on 
positive-going clock transitions; 
asynchronous data does not 
require a transmit clock.
3
BB
104
Receive
d Data
Serial digital data output to the 
DTE interface: Sync data is 
accompanied by an internal data 
rate (receive) clock (pin 17) that 
has positive-going transitions on 
the data transition. Async data 
does not require a receive clock.
4
CA
105
Request 
to Send
A positive level to the modem 
when data transmission is desired
5
CB
106
Clear to 
Send
A positive level from the modem 
in response to Request to Send and 
when the modem is ready to 
transmit. *
6
CC
107
Data Set 
Ready
A positive level from the modem 
when power is on and ready to 
operate: In dial-up operation, the 
modem must be off hook to give a 
high DSR signal.*
*
* Modem options may force these signals on or cause them to be ignored. 
*
*
†  This function can be disabled or its logic sense reversed by hardware straps.