Campbell Manufacturing R410 Manual De Usuario
I-
1
Appendix I. Phone to RF400 Series
Where a phone to RF400 Base
is desired, the following configurations will
provide Point-to-Point or Point-to-Multipoint communications. To have a base
datalogger in this configuration requires that another RF400 be added at the
base.
datalogger in this configuration requires that another RF400 be added at the
base.
1.
HARDWARE REQUIREMENTS
a.
RF400s
b.
COM210
c.
PS512M (or CH512R and battery)
(have built-in null-modems and supply power for RF400 and
COM210)
(have built-in null-modems and supply power for RF400 and
COM210)
d.
AC charger (CSI Item # 9591) or solar panel
e.
Two SC12 cables (one included with RF400 and one with COM210)
2.
POINT-TO-POINT COMMUNICATIONS
PC-Modem ------------ COM210-PS512M-RF400------------ RF400-DL
(null-modem)
LoggerNet SETUP
a.
Setup:
ComPort_1
PhoneBase
PhoneRemote
RF400
RF400Remote
CR10X
b. ComPort_1 – default settings
c.
PhoneBase
1) Maximum Baud Rate – 9600
2). Modem Pick List – per PC’s phone modem
3) Extra Response Time – 0 s
2). Modem Pick List – per PC’s phone modem
3) Extra Response Time – 0 s
d. PhoneRemote – input base site’s phone number
e. RF400 – make Attention Character: “-“ ; leave the rest defaults
f. RF400Remote – Radio Address: “0” ; leave the rest defaults
g.
CR10X – default settings, schedule collections as desired
PC208W SETUP
a.
Device Map
COM1
Modem1
CR10X1
b. COM port - Default settings