Cisco Systems 78-12510-02 Manual De Usuario

Descargar
Página de 20
5-17
Cisco MGX Route Processor Module (RPM-PR) Installation and Configuration Guide
Release 2.1, Part Number 78-12510-02 Rev. C1, August 31, 2004
Chapter 5      Configuring the MGX RPM-PR
Establishing 1:N Redundancy Between Two or More RPM-PR Cards
Note
After you enter the addred command, the switch resets the secondary card; therefore, the
secondary card will be unavailable for a few minutes.
Step 5
When the reset is complete, enter the dspcds command to show the primary and secondary cards in the
active and standby states, respectively.
The redundant RPM cards are shown in slots 2 and 11 with the standby card in slot 11.
Switch.7.PXM.a > dspcds
Switch
 System Rev: 02.01   Mar. 19, 2001 23:14:58 GMT
Chassis Serial No:   SAA03230404 Chassis Rev: B0     GMT Offset: 0
                                                     Node Alarm: MAJOR
Card  Front/Back          Card           Alarm      Redundant   Redundancy
Slot  Card State          Type           Status     Slot        Type
---   ----------          --------       --------   -------     -----
01    Empty               ---            ---        ---         ---
02    Active/Empty        RPM-PR         NONE       11          PRIMARY SLOT
03    Empty               ---            ---        ---         ---
04    Empty               ---            ---        ---         ---
05    Empty               ---            ---        ---         ---
06    Failed/Empty        AXSM_1OC48     MINOR      NA          NO REDUNDANCY
07    Active/Active       PXM45          NONE       08          PRIMARY SLOT
08    Empty Resvd/Empty   ---            MAJOR      07          SECONDARY SLOT
09
Empty               ---            ---        ---         ---
10    Empty               ---            ---        ---         ---
11
Standby/Empty       RPM-PR         NONE       11          SECONDARY SLOT
12    Empty               ---            ---        ---         ---
13    Empty               ---            ---        ---         ---
14    Empty               ---            ---        ---         ---
Step 6
To display the redundancy relationship between all cards in the switch, enter the dspred command.
Redundant cards are displayed as shown below, indicating primary and secondary slot numbers, card
types, card states, and redundancy type.
Switch.7.PXM.a > dspred
Switch
System Rev: 02.01   Mar. 19, 2001 23:15:37 GMT
MGX8850                                              Node Alarm: MAJOR
Primary  Primary   Primary    Secondary  Secondary  Secondary    Redundancy
SlotNum   Type      State      SlotNum     Type       State         Type
-------  -------  ---------   ---------  ---------  ---------    ----------
  2      RPM-PR    Active        11
 RPM-PR     Standby
1-n
  7      PXM45     Active        8        PXM45      Empty Resvd    1-1
Step 7
Return to the primary RPM by entering the cc command, cc <redPrimarySlotNum>.
Unknown.7.PXM.a > cc 2
Step 8
Enter copy run start to save the configuration to the PXM-45 hard disk E:RPM directory.
This file will be used as the configuration file. The name of the file is auto_config_slotwhere is the
primary slot number.
Note
This step is mandatory for redundancy to work.