Troubleshooting the Line Card
Monitoring Critical, Major, and Minor Alarm Status
Alarms warn of:
Overtemperature condition on a component in the card
Fan failure in the fan tray
Overcurrent condition in a power supply
Out-of-tolerance voltage on the card
The alarm LEDs are controlled by the CAN microcontoller software, which sets the threshold levels for 
triggering the different stages of alarms.
The RP card continuously polls the system for temperature, voltage, current, and fan speed values. If a 
threshold value is exceeded, the RP sets the appropriate alarm severity level on the alarm card, which 
lights the corresponding LED, and energizes the appropriate alarm display relays to activate any external 
audible or visual alarms wired to the alarm display. The RP also logs a message about the threshold 
violation on the system console.
Note
If one or more of the alarm LEDs is on, check the system console for messages describing the alarm.
Troubleshooting the Line Card
Initial Boot Process
During a typical line card boot process, thse events occur:
1.
The line card receives power and begins executing initialization software.
2.
The line card performs internal checks, and prepares to accept the Cisco IOS XR software from the 
RP.
3.
The RP loads the line card with its Cisco IOS XR software.
To verify that the line card is working properly:
Step 1
Check that the LC FAIL LED is ON (green) to verify that the card is operating normally. 
Step 2
Check that the RSP FAIL LED for the port of interest is ON (green or blinking) to verify that the port is 
active. If the RSP FAIL LED is not ON, verify that the associated interface is not shut down.
Step 3
If one of the conditions above is not met, see the 
 to identify any possible problems.
Status LEDs
You can use the LC FAIL LED or the RSP FAIL LED on the RP card front panel to verify proper 
operation or troubleshoot a failure (see 
).