Now, right click in the H
ELD 
C
OMMAND
 column for Logic Input 1 and select I
NSERT
, I
NPUT
, 1, M
UTE
O
FF
.   Now, whenever the switch goes Active Low (0V DC), the Vortex Device will unmute Input 1. 
 
 
  
If you are successful, you should see this on the screen: 
 
 
  
Make sure that the physical wiring works by pressing and holding the membrane switch.  You 
should see the LED above the pin assignment lit in green: 
 
 
  
Repeat the above process for each MX392 microphone that you want to connect to the Vortex 
Device. 
  
 
 
 
 
 
 
 