Gateway p-79 Manual De Usuario

Descargar
Página de 198
154
Devices
The notebook doesn’t enter standby mode after 
closing the LCD.
Make sure that the magnet is in the magnet holder. For more 
information, see 
Test or replace the system board.
The system doesn't resume from hibernation 
mode.
Check the hard disk connection to the system board.
Test or replace the hard disk drive.
Test or replace the system board.
The system doesn't resume from standby mode 
after opening the LCD.
Make sure that the magnet is in the magnet holder. For more 
information, see 
Test or replace the system board.
The battery fuel gauge in Windows doesn’t go 
higher than 90%. 
Remove the battery pack and let it cool for two hours.
Refresh the battery (use only battery power until the notebook turns 
off, then charge the battery).
Test or replace the battery pack.
Test or replace the system board.
The system hangs intermittently.
Reconnect the hard disk drive and optical drive.
Check the hard disk connection to the system board.
Test or replace the system board.
Symptom / Error
Action in Sequence
System configuration does not match the 
installed devices. 
Run “Load Setup Defaults” using the BIOS Setup Utility, then reboot 
the notebook.
Reconnect the hard disk drive and optical drive.
The external display does not work correctly.
Press Fn+F4 repeatedly to switch between LCD, external display, and 
both displays.
Test or replace the system board.
USB does not work correctly.
Test or replace the USB board.
Test or replace the system board.
Printer problems.
Run the printer self-test.
Reinstall the printer driver.
Test or replace the printer cable.
Test or replace the printer.
Test or replace the system board.
Symptom / Error