Renesas M16C/6NK Manual De Usuario

Descargar
Página de 340
Rev.1.10    Jul 01, 2005    page 79 of 318
REJ09B0124-0110
M16C/6N Group (M16C/6NK, M16C/6NM)
9. Interrupt
Under development
This document is under development and its contents are subject to change.
Figure 9.16  AIER Register, AIER2 Register and RMAD0 to RMAD3 Registers
RW
-
Address Match Interrupt Enable Register
Address Match Interrupt 0
Enable Bit
Address Match Interrupt 1
Enable Bit
0 : Interrupt disabled
1 : Interrupt enabled
0 : Interrupt disabled
1 : Interrupt enabled
Symbol
Address
After Reset
AIER
 0009h
XXXXXX00b
AIER0
AIER1
-
(b7-b2)
RW
Bit Name
Function
Bit Symbol
RW
Nothing is assigned. When write, set to "0".
When read, their contents are indeterminate. 
b7
b6
b5
b4
b3
b2
b1
b0
RW
-
Address Match Interrupt Enable Register 2
Address Match Interrupt 2
Enable Bit
Address Match Interrupt 3
Enable Bit
0 : Interrupt disabled
1 : Interrupt enabled
0 : Interrupt disabled
1 : Interrupt enabled
Symbol
Address
After Reset
AIER2
01BBh
XXXXXX00b
AIER20
AIER21
-
(b7-b2)
RW
Bit Name
Function
Bit Symbol
RW
Nothing is assigned. When write, set to "0".
When read, their contents are indeterminate. 
b7
b6
b5
b4
b3
b2
b1
b0
RW
-
-
(b19-b0)
-
(b23-b20)
Bit Symbol
Address
Symbol
After Reset
0012h to 0010h
0016h to 0014h
01BAh to 01B8h
01BEh to 01BCh
RMAD0
RMAD1
RMAD2
RMAD3
X00000h
X00000h
X00000h
X00000h
Function
Setting Range
RW
Address setting register for address 
match interrupt
Nothing is assigned. When write, set to "0". 
When read, their contents are indeterminate.
Address Match Interrupt Register i (i = 0 to 3)
00000h to FFFFFh
b0 b7
b0
b3
(b19)
(b16)
b7
b0
(b15)
(b8)
b7
(b23)