Chapter 9      Removing and Installing the NPE or NSE
Removing and Replacing the NPE or NSE
Caution
When inserting SIMMs, use firm but not excessive pressure. If you damage a socket, you must return the 
network processing engine or network services engine to the factory for repair.
Step 6
Gently push the SIMM into the socket until the spring latches snap over the ends of the SIMM. If 
necessary, rock the SIMM gently back and forth to seat it properly.
Step 7
Repeat Step 2 through Step 6 for the remaining SIMMs.
Step 8
When all SIMMs are installed, check all alignment holes (two on each SIMM) and ensure that the spring 
latch is visible. If it is not, the SIMM is not seated properly. If any SIMM appears misaligned, carefully 
remove it and reseat it in the socket. Push the SIMM firmly back into the socket until the spring latches 
snap into place.
This completes the SIMM replacement procedure. Proceed to the 
Removing SDRAM DIMMs
The procedures in this section are required only if you have an NPE-175, NPE-225, NPE-300, or NSE-1 
and need to upgrade or replace the SDRAM DIMMs. On the NPE-175, NPE-225, and NSE-1, the 
SDRAM DIMMs are located in socket U15. The two user-configurable SDRAM DIMMs on the 
NPE-300 are located in sockets U45 and U44. 
Note
The NPE-300 contains two banks of SDRAM. Both SDRAM banks are used for all packet memory 
requirements; however, bank 0 is used exclusively for packet memory and is set at a fixed configuration 
in the factory.
 
 
Bank 1 contains two user-configurable SDRAM slots, DIMM slot 2 and DIMM slot 3 (see 
 th
). Both slots in bank 1 can 
be populated by DIMMs of different sizes; however, the size of the DIMM in slot 2 must be greater than 
or equal to the size of the DIMM in slot 3, and the size of the DIMM in slot 3 can be zero.
Note
Use only SDRAM DIMMs supplied by Cisco.
Use the following procedure to remove the existing DIMMs:
Step 1
Turn off the system power and remove the network processing engine or network services engine from 
the system. (Follow the steps in the 
.)
Step 2
Place the network processing engine or network services engine on an antistatic mat or pad and ensure 
that you are wearing an antistatic device, such as a wrist strap. 
Step 3
Locate the DIMM and position the network processing engine or network services engine so that you are 
facing the DIMM you want to remove.
Step 4
Open the DIMM socket latches on the DIMM to release the DIMM from the socket. (See 
.) 
The DIMM is under tension in the socket; therefore, the DIMM might be released from the socket with 
some force.