Cisco Systems SLM224G4PS Manual De Usuario

Descargar
Página de 78
54
About Switch Stacking
24/48-Port 10/100 + 4-Port Gigabit Smart Switch with Resilient Clustering Technology and PoE
Appendix B
If both duplicate units are in auto (self ordering) mode, 
then the unit ID will be decided by the Mac address. 
The unit with the lower Mac will keep its unit ID. The 
other will be reassigned a new unit ID.
If  one  of  the  duplicates  is  in  auto  (self  ordering) 
mode and the other unit is in manual mode then the 
manual mode unit will keep its ID and the other will be 
reassigned a new unit ID.
If both duplicate units are in manual mode then both 
of them will be shut down.
If the stack Master is able to allocate a unique Unit ID to 
each unit, then all units can operate as a stack. If the stack 
Master is unable to allocate a Unit ID to any unit, that unit 
is  effectively  shut  down  and  will  not  participate  in  the 
stack. 
In particular, units with a conflicting manually set Unit ID 
number  will  be  shut  down  because  the  Master  cannot 
override the system administrator’s assignment to resolve 
the conflict. 
If there are more units than the maximum number allowed 
in  a  stack  and  the  incoming  units  are  already  in  factory 
default  state  (which  means  they  do  not  have  unit  ID 
assigned) then a Master will be elected following Master 
Discovery and Master Election processes. All other units 
will remain shut down. Please note that in some extreme 
cases,  due  to  a  race  condition  during  the  boot  process, 
some of the units might be connected and join the stack.. 
If the incoming units already have a unit ID then none of 
them will join the stack and all will be left in shutdown 
mode (since there is no way to know which of them are 
preferable).
NOTE:
  If  a  unit  is  shut  down,  its  stacking 
links will be inactive. Moreover, if the stacking 
units  are  connected  in  a  chain  topology,  the 
shutdown of one unit breaks the chain and may 
cause other units to be shut down if they have 
no active link to the Master unit.
Unit and Port Configuration
At this point, each unit in the stack has a unique Unit-ID; 
one of the units is the stack Master, and, possibly, one of 
the units serves as Backup Master. The stack Master will 
now  configure  each  of  the  member  units  and  its  ports 
according to the configuration file present on the Master. 
If the stack has a Backup Master the configuration file will 
also be copied to the Backup Master.
Once all the units and ports are configured, the stack will 
go into normal operational mode. If any change is made 
to the system configuration, the change will be stored by 
the stack Master and will be copied to the Backup Master 
(if it exists).
User Controls
Using either the CLI or the graphical user interface (GUI), 
the user can configure the following settings:
Set the operational mode of the unit (which will take 
effect after next reboot) – Standalone or Stack.
Force a unit to be the stack Master after the next reset
Assign  a  static  Unit  ID,  or,  allow  the  unit  to  be 
renumbered.
Stacking Examples
Replacing a Failed Stack Member in a Running 
Stack
In this example, a non-master unit fails in a running stack. 
When  notified  of  the  failure,  a  system  administrator 
removes the failed unit and replaces it with another one.
When  the  unit  fails,  the  stack  Master  detects  (via  the 
ongoing Master Discovery process) that the unit no longer 
responds,  and  directs  all  other  stack  members  to  route 
unit-to-unit  traffic  around  the  failed  unit  using  the  ring 
topology of the stacking connections. At the same time 
the stack Master notifies the system administrator (using 
SYSLOG messages and SNMP traps) of the failure.
When  the  failed  unit  is  disconnected  from  the  stack,  all 
traffic will already be routed around it, and as long as all 
other stacking connections are left intact, the stack should 
continue to run.
When a new unit is inserted in the stack and powered up, 
the following will happen: 
The incoming unit, being in stack mode, will perform 
Master discovery, and perhaps participate in a Master 
Election,  as  described  above  for  any  stacking-mode 
unit powering up.
If the incoming unit has a Unit ID of 1 or 2, i.e. it 
is a master enabled unit, it will initiate a Master 
Election. However, since the running stack Master 
has a longer run time, it will remain elected as 
the stack Master and the incoming unit will not 
become a new stack Master.
If the incoming unit has a Unit ID of 3 to 6 (3 to 4 for 
SLM248G4PS), it will try to become a member unit 
of the stack subject to the already running stack 
Master, and Master Election will not take place.
The stack Master at this stage will carry out a Unit ID 
allocation and conflict resolution process.
1.