Server /chassis/storageadapter #
carve-virtual-drive
< Fetching virtual drives...>
ID
Name
RL
VDSize
MaxPossibleSize PD(s)
----------------------------------------------------------------
3
test_v_drive
1
1000 MB
67664 MB
6,7
Please choose from the above list the virtual drive number
whose space the new virtual drive will share-->
3
New virtual drive will share space with VD 3
Please enter Virtual Drive name (15 characters maximum)-->
new_from_test
Please enter Virtual Drive size in MB, GB, or TB (maximum: 67664 MB)
Example format: '400 GB' -->
500 MB
Optional attribute:
Write Policy: defaults to Write Back
OK? (y or n)-->
y
New virtual drive will have the following characteristics:
- It will share space with virtual drive 3
- Name: 'new_from_test'
- Size: 500 MB
OK? (y or n)--> y
Server /chassis/storageadapter #
show virtual-drive
Virtual Drive Health
Status
Name
Size
RAID Level
Boot Drive
------------- -------------- -------------------- ---------------- ---------- ----------
----------
0
Good
Optimal
150528 MB
RAID 0
false
1
Good
Optimal
20480 MB
RAID 0
true
2
Good
Optimal
114140 MB
RAID 0
false
3
Good
Optimal
test_v_drive
1000 MB
RAID 1
false
4
Good
Optimal
new_from_test
500 MB
RAID 1
false
Server /chassis/storageadapter #
Clearing Foreign Configuration
This task clears all foreign configuration on the controller. Also, all configuration information from all
physical drives hosting foreign configuration is deleted. This action cannot be reverted.
Important
Before You Begin
You must log in with admin privileges to perform this task.
Procedure
Purpose
Command or Action
Enters the chassis command mode.
Server# scope chassis
Step 1
Enters command mode for an installed storage card.
Server /chassis # scope storageadapter
slot
Step 2
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5    
   OL-28893-01
117
Managing Network Adapters
Clearing Foreign Configuration