Cisco Systems 57712 Manual De Usuario

Descargar
Página de 288
Purpose
Command or Action
The changes will take effect upon the next server
reboot.
Note
This example deletes a vNIC on adapter 1:
Server#
scope chassis
Server /chassis #
scope adapter 1
Server /chassis/adapter #
delete host-eth-if Vnic5
Server /chassis/adapter *#
commit
Server /chassis/adapter #
Configuring iSCSI Boot Capability
Configuring iSCSI Boot Capability for vNICs
When the rack-servers are configured in a standalone mode, and when the VIC adapters are directly attached
to the Nexus 5000 family of switches, you can configure these VIC adapters to boot the servers remotely from
iSCSI storage targets. You can configure Ethernet vNICs to enable a rack server to load the host OS image
from remote iSCSI target devices.
To configure the iSCSI boot capability on a vNIC:
• You must log in with admin privileges to perform this task.
• To configure a vNIC to boot a server remotely from an iSCSI storage target, you must enable the PXE
boot option on the vNIC.
You can configure a maximum of 2 iSCSI vNICs for each host.
Note
Configuring iSCSI Boot Capability on a vNIC
You can configure a maximum of 2 iSCSI vNICs for each host.
Before You Begin
• To configure a vNIC to boot a server remotely from an iSCSI storage target, you must enable the PXE
boot option on the vNIC.
• You must log in with admin privileges to perform this task.
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5    
   OL-28893-01
107
Managing Network Adapters
Configuring iSCSI Boot Capability