Managing Storage Adapters
Create Virtual Drive from Unused Physical Drives
Before You Begin
You must log in with admin privileges to perform this task.
Procedure
Purpose
Command or Action
Enters the chassis command mode.
Server# scope chassis
Step 1
Enters command mode for an installed storage card.
Server /chassis # scope
storageadapter 
slot
Step 2
At this point, you are prompted to enter information
corresponding to the RAID level, the physical drives to be
Server /chassis/storageadapter #
create virtual-drive
Step 3
used, the size and the write policy for the new virtual drive.
Enter the appropriate information at each prompt.
When you have finished specifying the virtual drive
information, you are prompted to confirm that the
information is correct. Enter (yes) to confirm, or (no)
to cancel the operation.
Displays the existing virtual drives.
Server /chassis/storageadapter #
show virtual-drive
Step 4
This example shows how to create a new virtual drive that spans two unused physical drives.
Server#
scope chassis
Server /chassis #
scope storageadapter SLOT-3
Server /chassis/storageadapter #
create-virtual-drive
Please enter RAID level
(0, 1, 5, 6, 10, 50, 60) -->
1
Please choose from the following 2 unused physical drives:
Slot 6: size 68664 MB
Slot 7: size 68664 MB
Specify physical disks for span 0:
Enter comma-separated PDs from above list-->
6,7
Please enter Virtual Drive name (15 characters maximum)-->
test_v_drive
Please enter Virtual Drive size in MB, GB, or TB
Example format: '400 GB' -->
1000 MB
Optional attribute:
Write Policy: defaults to Write Back
OK? (y or n)--> n
0: Write Through
1: Write Back
2: Write Back with Bad BBU
3: Write Back Adaptive
Choose number from above options-->
2