When setting the address (via the dipswitch) use the silkscreen 
on the printed circuit board. This silkscreen shows a “1” and a “0” to 
refer to the “on and “off” states that each switch is set to. Switch S1 
configures port one (labeled J1) and, on two port cards, switch S2 
configures port two (labeled J2). Least significant bit (LSB) and most 
significant bit (MSB) are labeled on the card. Table 1 shows the 
numerical weight and electrical connection of each switch position. 
Refer to Table 2 for COM port addresses. Table 3 shows frequently 
unused port addresses for applications when COM port addresses 
1-4 are already used. 
 
 
To install the 3PXCC card as COM1, 2, 3, or 4, follow the switch 
settings shown in Table 2. To install at another address, follow the 
switch settings shown in Table 3. 
Table 2.  Standard Port Addresses 
 
Table 1.  Address Switches 
Switch 
Position 7 6 5 4 3 2 1 
Bus Connection  SA9 SA8  SA7 SA6 SA5  SA4 SA3
Decimal Weight 
512 256  128 64 
  32  16  8 
Hex Weight 
200 100 80 40 20  10 8 
 
 Base 
Hex 
Address 
Binary 
Equivalent 
Switch Settings 
MSB       LSB 
7654321 
COM1 
3F8 1111111000  1111111 
COM2 
2F8 1011111000  1011111 
COM3 
3E8 1111101000  1111101 
COM4 
2E8 1011101000  1011101 
 
32  
Documentation 
No.3PXCC1x-2x-3903 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 
Table 3.  Frequently Unused Port Addresses 
 
Interrupt Jumper Setup 
 
The IRQ is a hardware Interrupt Request line in an ISA Bus 
expansion slot on a PC or AT compatible computer. The 8 bit PC 
ISA slot has 8 interrupts, the 16 bit slot has another 7 since one of 
the first 8 is used to link in the remaining 8. The IRQ is used by 
devices to request immediate service by the main microprocessor. 
When the IRQ line is set, the microprocessor stops whatever it’s 
doing, saves status, checks which line was set, then jumps to code 
to handle the interrupt. The processor then clears the interrupt and 
returns to what it was doing before. IRQ lines are set by the internal 
timer, keyboard, hard drive controller, PCI, USB controller, sound 
card, serial ports, printer and more. The 3PXCC2 serial cards 
include special circuitry which allows one IRQ to be shared between 
the cards two ports even during simultaneous use. The software 
driver must support shared IRQs for this feature to work. Both 
Windows 9x and NT support shared IRQs. To configure both ports 
of the card to share one IRQ, set both jumpers of JP4 to the “Share” 
position. The Port 1 IRQ Select jumper should then be set to the 
desired IRQ. The Port 2 IRQ Select jumper is ignored when in 
shared mode. 
 
The 3PXCC cards allow the use of interrupts (IRQ) 2, 3, 4, 5, 6, 
7, 10, 11, 12, 14, and 15. Table 4 shows the standard serial port IRQ 
settings. NOTE: If two ports use the same IRQ setting, both ports 
cannot use the serial port at once. Only one port at a time may 
communicate. 
Base 
Hex 
Address
Binary 
Equivalent 
Switch 
Settings 
MSB       LSB 
7654321 
I/O Space 
Description 
200 
1000000000 1000000 game 
port 
208 
1000001000 1000001 game 
port 
300 
1100000000 1100000 prototype 
308 
1100001000 1100001 prototype 
310 
1100010000 1100010 prototype 
318 
1100011000 1100011 prototype 
380 
1110000000 1110000 SDLC 
388 
1110001000 1110001 SDLC 
3A0 
1110100000 1110100 bisync 
com 
3A8 
1110101000 1110101 bisync 
com