B&B Electronics ZP Series Manual De Usuario

Descargar
Página de 70
64 
Manual Documentation Number: ZP24D-250RM-SR-2508 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
 
AT Command Response 
API Identifier Value: 0x88 
Response to previous command. 
 
In response to an AT Command message, the module will send an AT Command 
Response message.  Some commands will send back multiple frames (for example, 
the ND (Node Discover) and AS (Active Scan) commands). These commands will end 
by sending a frame with a status of ATCMD_OK and no cmdData. 
 
AT Command Response Frames. 
 
 
 
TX (Transmit) Request: 64-bit address 
API Identifier Value: 0x00 
A TX Request message will cause the module to send RF Data as an RF Packet. 
 
TX Packet (64 bit address) Frames 
 
 
 
TX (Transmit) Request: 16-bit address 
API Identifier Value: 0x01 
A TX Request message will cause the module to send RF Data as an RF Packet. 
 
TX Packet (16 bit address) Frames