485SDD16-1005 Manual 
Appendix D 
D-1 
B&B Electronics  --  707 Dayton Road  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815) 433-5104
 
APPENDIX D 
Adding Data Field Comfirmation
 
D-2 
Appendix D 
485SDD16-1005 Manual 
B&B Electronics  --  707 Dayton Road  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815) 433-5104
 
With serial communications in a laboratory environment, the 
possibility of a communication error occurring is minimal.  However, 
in a harsh or an industrial environment the possibility increases.  A 
communication error occurs when a bit transmitted as a “1” is 
received as a “0” or vice versa.  If the 485SDD16 receives a error in 
one or more of the first four command characters (“!0xx”), the unit 
will not execute the command.  However, if the 485SDD16 receives 
an communication error on a  data byte (I/O byte for Read Digital 
command or state byte for Set Output State command), the 
command will be executed since the unit has no way of knowing that 
there was an error. 
To provide the 485SDD16 with a way of detecting errors in the 
data fields, an additional set of commands can be used.  This set of 
commands begins with the “#” (23h) character, instead of the “!” 
(21h) character.  Refer to Table D-1.  With these commands every 
data byte that is transmitted or received is followed by its 
complement.  For example:  To read I/O lines: 
Command syntax: 
#{addr}RD  
Response syntax: 
{I/O msb}{~ I/O msb}{I/O lsb} {~ I/O lsb} 
Where “~” is used to indicate the “complement of.”  If I/O has a 
reading of 1, the following would be received: 
{00}{FF}{01}{FE} 
Where FFh is the complement of 0 and FEh is the complement of 
1.  The complement of number “x” can be calculated in QuickBasic 
as follows: 
comp = (NOT x) AND &HFF