Connect Tech Blue Heat/PCI PCI Serial Communications Manual De Usuario

Descargar
Página de 47
Blue Heat/PCI User’s Manual, Connect Tech Inc. 
 
Revision 0.11  
 
36 
 
Half Duplex Mode  
In this mode the TxD line driver is enabled only when data is transmitted and RxD is disabled 
when data is being transmitted. This mode is typically used in either point to point "2 wire" 
connections OR in multi-drop "2 wire" bus connections.  To enable this mode for a port you 
must jumper positions 7 and 8 on the appropriate jumper blocks JA, JB, JC, JD.  These jumpers 
short TxD – to RxD – and TxD + to RxD +. 
 depicts the locations of jumper blocks JA, 
JB, JC and JD. 
 
 
Example 
The following example shows the settings on JA, JB, JC and JD 
where the RS-422/485 port 1 is set half duplex, the RS-422/485 
port 2 is set for half duplex; RS-422/485 port 3 is set for full 
duplex or multi-drop slave, and the RS-422/485 port 4 is set for 
full duplex or multi-drop slave.
 
 
JD1 
JB
JC 
JD2 
JD3 
JD4 
JD5 
JD6 
JD7 
JD8 
JD JA
COM4 
JC1
JC2
JC3
JC4
JC5
JC6
JC7
JC8
COM3 
JB1
JB2
JB3
JB4
JB5
JB6
JB7
JB8
COM2 
JA1
JA2
JA3
JA4
JA5
JA6
JA7
JA8
COM1 
RTS ± TERM 
TXD ± TERM 
CTS ± BIAS 
CTS ± BIAS 
RXD ± BIAS 
RXD ± BIAS 
Insert for 1/2 D
Insert for 1/2 D
 
 
 
Technical Notes: 
If you wish to set a specific port for half duplex, you must 
jumper both positions 7 and 8 on the appropriate jumper block. 
For RS-232 ports do not jumper any positions on the 
appropriate JA, JB, JC and JD jumper block. 
 
Multi-drop Slave Mode 
In this mode the TxD line driver is enabled only when data is transmitted and RxD is enabled all 
the time.  This mode is typically used in multi-drop "4 wire" connections. 
 
Tri-state Control 
The Blue Heat/PCI Opto adapters allow you to tri-state the line drivers on power up.  To tri-state 
the drivers on power up please make certain there is no jumper installed across the pins on 
jumper block JI.  Please refer to 
 for the location of J1. 
 
Example 
The following example shows the settings on J1 to tri-state the 
transceivers upon power up of the Blue Heat/PCI Opto 
adapter. 
 
J1 
RS485 TX Power up
ON = ENABLED 
OFF = DISABLED 
 
1.