EPIMs
A-4
EPIM-C
The EPIM-C supports thin-net coaxial cabling and is equipped with an internal 
Cabletron Systems TMS-3™ Transceiver. You can use the TERM switch on the 
front of the EPIM-C to set the internal 50-ohm terminator. This eliminates the 
need to connect the port to a tee-connector and terminator. Figure A-4 shows the 
setting for the terminator switch.
Table A-3. EPIM-F3 Specifications
Parameter
Typical Minimum
Maximum
Transmitter Peak Wave Length
1300 nm
1270 nm
1330 nm
Spectral Width
60 nm
-
100 nm
Rise Time
3.0 nsec
2.7 nsec
5.0 nsec
Fall Time
2.5 nsec
2.2 nsec
5.0 nsec
Duty Cycle
50.1%
49.6%
50.7%
Bit Error Rate
Better than 10
-10
Transmitter Power decreases as temperatures rise and increases as temperatures 
fall. Use the Output Power Coefficient to calculate increased or decreased power 
output for your operating environment. For example, the typical power output at 
25
°
C is -16.4 dBm. For a 4
°
C temperature increase, multiply the typical 
coefficient (-0.15 dBm) by four and add the result to typical output power (4 x -
0.15 dBm + -16.4 = -17.0).
NOTE
The transmitter power levels given above are Peak Power Levels after optical 
overshoot. You must use a Peak Power Meter to correctly compare the values 
given above to those measured on any particular port. If you are measuring power 
levels with an Average Power Meter, add 3 dBm to the average power 
measurement to correctly compare the average power values measured to the 
values listed above (i.e., -33.5 dBm average + 3 dB = -30.5 dBm peak).