Cabletron Systems SSIM-T5-04 Prospecto

Descargar
Página de 2
1
2
3
SSIM-T5-04 Token Ring 
SmartStack Interface Module 
Introduction
The SmartStack SSIM-T5-04 provides four additional Token 
Ring ports for the base SmartStack STS16-20RM or STS16-
20FRM Token Ring switch. These ports can be configured just 
like the 20 fixed Token Ring ports on the base switch. Each or 
all of the interface module ports can be configured (in 
combination with any of the fixed ports on the base switch) to 
be used in CrossLink connections, and configured to be 
included in virtual LANs. The interface module ports support 
address filters and BOOTP/TFTP, Telnet or SNMP sessions.
Figure 1.  SSIM-T5-04 interface module Front Panel
The ports on the SSIM-T5-04 interface module support Token 
Ring twisted-pair (UTP/STP) media via RJ-45 connectors. 
The interface module ports can be configured just like the base 
switch ports to provide either shared (half-duplex) 4 or 16 
Mbps Token Ring connections or dedicated (full-duplex) 32 
Mbps connections.
In addition to the RJ-45 Token-Ring connectors, there are 10 
LEDs on the faceplate of the interface module (a set of two for 
each port plus two for the interface module general status). 
These LEDs indicate the operational status of the interface 
module and of the ports.
SSIM-T5-04 Module Package Contents
The interface module package contains the following items:
One SSIM-T5-04 SmartStack interface module for the 
Token Ring Switch
One SSIM-T5-04 SmartStack Interface Module 
Installation Guide (this document)
Installation
1. Power off the base switch by unplugging it.
2. Remove the plate covering the expansion slot on the front 
of the base switch by unscrewing the two retaining 
thumbscrews. Keep the plate for use in the event that the 
interface module is removed.
3. Carefully insert the interface module into the rails on each 
side of the expansion slot, sliding it back until the 
connector on the interface module is seated into the 
connector at the back of the slot.When the interface 
module is fully seated, the interface module faceplate will 
be flush with the front of the base switch.
4. Secure the interface module with the two attached 
thumbscrews.
Cabling
For specifications and directions about cabling the UTP/STP 
universal expansion modules, see Appendix B in SmartStack 
STS16-20RM/STS16-20FRM Token Ring Switches, 
Installation and User Guide
.
LEDs
The interface module has 10 LEDs.
Table 1 lists the two status LEDs on the left front of the 
interface module and their meanings.
Table 1.  Status LEDs and their meanings
Table 2 lists the port LEDs above each RJ-45 and their 
meanings.
Table 2.  Port LEDs and their Meanings
Testing the interface module
1. Power on the base switch to start diagnostics. The STS16-
20RM Token Ring switch indicates that diagnostics are in 
progress by turning on its DIAG LED. After about a 
minute, the interface module DIAG LED will also be 
turned on.
2. Verify that the base switch diagnostics have been 
completed successfully. On the STS16-20RM, this is 
indicated when its DIAG LED is turned off, and the ERR 
LED stays turned off. Diagnostics can take up to four 
minutes to complete.
3. Verify that the ERR LED on the interface module is off. If 
it is off, diagnostics have been successfully completed, and 
the interface module is ready for configuration.
Configuration
The interface module ports can be configured just like the base 
switch ports. They will appear as additional ports on any 
configuration panel where ports are listed. The port numbers 
will begin where the numbers of the base switch stop.
If for example the base switch has 20 ports and an interface 
module in the left front panel slot, the interface module ports 
will appear after Port 20 on the various port configuration 
panels and be designated 21, 22, 23 and 24. If the module is in 
the right front panel slot, the ports will be designated 25, 26, 
27 and 28.
Follow the instructions contained in the SmartStack STS16-
20RM/STS16-20FRM Token Ring Switches, Installation and 
User Guide
 for configuring the interface module ports.
ERR
DIAG
2
3
4
1
LED
Position
State
Meaning
DIAG 
(green)
Top
On
Diagnostics are in 
progress.
Off
The interface module is 
working correctly.
ERR 
(yellow)
Bottom
On
An interface module 
failure has occurred.
Off
The interface module is 
working correctly.
LED
Position
State
Meaning
INSRT 
(green)
Left
On
The attached device is 
connected to the interface 
module port.
TX/RX 
(green)
Right
On or 
blinking
Data is being transmitted 
or received by the port.