Cabletron Systems 6H259-17 Manual De Usuario

Descargar
Página de 58
Troubleshooting Checklist
Troubleshooting
4-5
4.2
TROUBLESHOOTING CHECKLIST
If the SmartSwitch is not working properly, refer to 
 for a checklist of possible problems, 
causes, and recommended actions to resolve the problem.
Table 4-2
Fault Identification
Symptom
Possible Causes
All LEDs off.
1. Installation error - Remove the SmartSwitch and perform 
installation in accordance with installation instructions. Check 
connectors for dust or dirt and clean as necessary.
2. Power system fault - refer to 
.
Module stays in BOOT 
state.
1. Device does not have an operable firmware image, and is 
sending out BootP requests in an effort to locate a BootP server 
on the network. Press the RESET button on the front panel to 
attempt to use the firmware image in FLASH memory.
2. If the problem continues after pressing the RESET button, refer 
to 
 for instructions on forcing a BootP image 
download.
3. Contact Cabletron Systems if the problem continues.
Cannot access Local 
Management.
1. Firmware image fault - refer to 
.
2. Management system fault - refer to 
.
Cannot contact device 
through in-band 
management.
1. Management system fault - refer to 
.
2. No link to device - verify all network connections between the 
network management station and the SmartSwitch are valid and 
operating.
User parameters 
(IP address, 
community names, 
etc.) lost on reset or 
power-up.
Device setup fault - refer to 
.
Device is not 
forwarding traffic from 
any port.
Device setup fault - refer to 
.