MAKING NETWORK CONNECTIONS
Page 3-5
1
2
3
View B
4
1
2
3
5
View A
Figure 3-3. Attaching a Thin-Net Segment
3.2.2 Thin-Net Requirements
•
Cable -
Must be 50 ohm RG-58A type coaxial cable.
•
Length -
Must be no longer than 185 meters (607 ft.).
•
Termination -
A 50 ohm terminator at the far ends of each
thin-net segment.
•
Connections -
A maximum of 30 connections may be used
throughout a thin coaxial segment for host connections. If an
excessive number of barrel connections are used within the
cable segment, i.e. finished wall plates with BNC feed-
throughs, then a reduced number of host connections may be
required. For special network designs, contact Cabletron
Systems Technical Support.
excessive number of barrel connections are used within the
cable segment, i.e. finished wall plates with BNC feed-
throughs, then a reduced number of host connections may be
required. For special network designs, contact Cabletron
Systems Technical Support.
WARNING:
For safety, only one end of a thin-net segment should be
connected to earth ground. Connection to earth ground at more than one
point on the segment may allow for the occurrence of dangerous ground
currents.
point on the segment may allow for the occurrence of dangerous ground
currents.