Troubleshooting Checklist
Troubleshooting
4-9
Table 4-6
Device Setup Troubleshooting
Possible Causes
Instruction
The SmartSwitch detect a 
looped condition.
1. Verify that Spanning Tree is enabled. Refer to the Local 
Management User’s Guide for instructions on setting the 
type of STA.
2. Review network design and delete unnecessary loops.
Mode switch (7), 
NVRAM Reset, was 
changed sometime before 
either cycling power or 
pressing the RESET 
button, causing the 
user-entered parameters to 
reset to factory default 
settings.
1. Reenter the lost parameters as necessary. Refer to the Local 
Management User’s Guide for instructions on configuring 
the device through Local Management.
2. Call Cabletron Systems if the problem continues.
Clear NVRAM was set 
through Local 
Management.
1. Reenter the lost parameters as necessary. Refer to the Local 
Management User’s Guide for instructions on configuring 
the device through Local Management.
2. Call Cabletron Systems if the problem continues.