Attached Terminal or Modem Does Not Operate
4-3
Attached Terminal 
or Modem Does 
Not Operate
(Only if a local console or modem is attached) 
If a terminal or modem is attached to the console port and does not 
seem to be operating properly, follow the troubleshooting procedures 
recommended by the terminal/modem manufacturer. Also perform the 
following steps:
Make sure that the cable connections at both ends are secure.
Ensure that the cable attached to the AccessBuilder is the proper cable 
(straight-through for a terminal/PC and null modem for a modem).
If connecting to a terminal, a straight-through cable conforming to the 
VT-100 specification must be used. This applies only to the 
AccessBuilder 4000.
Check the console port configuration.
Refer to the “AccessBuilder Software Configuration Guide” for more 
information. Verify that the terminal/PC or modem is configured as 8 
data bits, no parity, one stop bit, 9600 baud rate, with flow control 
parameters set to Xon and Xoff (software flow control).
System Does Not 
Respond to 
Terminal 
Commands 
(Only if a local console is attached) 
If the AccessBuilder power is on but the terminal fails to respond to 
commands entered at the keyboard, try the following procedures:
Verify that a straight-through cable is used between the AccessBuilder 
and the terminal or workstation running the terminal emulator.
Power off the terminal, wait 30 seconds, and then power it on again.
If the system still does not respond to commands, power off the 
AccessBuilder and terminal and check the keyboard cable connection to 
ensure it is secure.
Power on the AccessBuilder and the terminal again.
Check the state of the LEDs on the front of the AccessBuilder as shown 