3com 4000 Manual De Usuario

Descargar
Página de 90
A
S
PECIFICATIONS
This appendix contains the hardware specifications for the 
AccessBuilder 4000 system.
Hardware 
Specifications
Table A-1   Environmental Specifications
Condition
Minimum
Maximum
Storage 
Temperature
-40
°
F (-40
°
C)
168
°
F (78
°
C)
Operating Temperature 32
°
F (0
°
C)
122
°
F (50
°
C)
Altitude
Sea Level
15,000 ft (4,570m)
Humidity
0%
95%
Heat Output
N/A
272 BTU/hr
Table A-2   Real-Time Clock Battery Specifications
Battery
Specification
Type
Ni-Cad, rechargeable, 3.6V/50mah
Duration
2 weeks without power
Recharge Capability
Fully charged within 2 days under power
Table A-3   Power Supply Specifications
Type
Value
AC Input
115V or 230V, autosensing
-22% to +10% single phase, 48 to 66 Hz, 100 watts 
maximum
DC Output
V1:     +5v/8.0Amps
V2:     +12V/3.0Amps
V3:     -12V/0.5A
V4:     -5V/0.5A
Fuse
230V / 3Amps
ab4kbook  Page 1  Thursday, March 27, 1997  11:51 AM